Model |
JAGUAR M6 |
|
Heating System |
Number of Heating Zone |
Top 6 Bottom 6 |
|
Heating Passage |
2500mm |
|
Heating Style |
Hot Air |
|
Number of Cooling Zone |
Up 1 Bottom 1 |
|
Cooling Style |
Forced Cooling air |
|
Conveyor System |
Max. Width of PCB |
300mm |
|
Mesh belt width |
400mm |
|
Conveyor Direction |
L→R(or R→L) |
|
Process Height |
900±20mm |
|
Conveyor Type |
Mesh belt and Chain conveyor |
|
Conveyor Speed |
0-1000mm/min |
|
Manual Lubrication |
Standard |
|
Hook Lift |
Electrical Screw Pole |
|
Fixed Rails side |
Front Track Fixed (Option: Rear Rail Fixed) |
|
Product Clearance |
Top and Bottom 30mm |
|
Control System |
Power Supply |
5line 3phase 380V 50/60Hz |
|
Total Power Consumption |
26kw |
|
Startup Consumption |
18kw |
|
Steady Consumption |
4-7KW |
|
Ramp Up Time |
About 20 mins |
|
Temp. Setting Range |
Room Temperature-300℃ |
|
Temp. Control Method |
PLC + PC |
|
Temp. Control Precision |
±1.5℃ |
|
Data Storage |
Process Data and Status Storage(80GB) |
|
Nozzle Plate |
Aluminum Alloy Plate |
|
Abnormal Alarm |
Abnormal Temperature. (Overtemp/Low temp.) |
|
Board Dropped Alarm |
Tower Light: Amber-warming, Green-normal, Red-abnormal |
|
General |
Dimension(L*W*H) |
3600×1100×1490mm |
|
Weight |
900KG |
|
Color |
Computer Grey |